BY - PASS ROTAMETER
This is a By- Pass line Rotameter for linear meassurement of-fluid flow in conjuction with orfice plates. This Provides an inexpensive method of measuring large flows beyond 20M3/ HR and line size-2" and above Model JTM -1005 Rotameter is Usedto measure flow regardless of main line pipe size. The unit consists of a complete assembly that is to be inserted in the main pipe line or Rotameter with Calibrated orifice plates which can be assembled to your By-Pass System.
JTM-1100
JTM-1300
SPECIFICATIONS
MAIN LINE MILD STEEL
  OPTION : S : MILD STEEL /RUBBER
  LINE / STAINLESS STEEL
END FITTING MILD STEEL/RUBBER LINED
  Option : M.S.R.L. S. S. FLANGED
BY PASS LINE 1/2" G. I. Pipe
  Option : 1/2" S.S. Pipe
ISOLATING VALVES 1/2" G. M. Gate Valves
  Option : 1/2" S. S. Gate Valves
ORIFICE PLATES S. S. Option : P.V.C.
ACCURACY + 2% at F. S.
MODEL
MAXIMUM FLOW M3/ HR WATER
LINE SIZE INCH/MM
JTM - 1120
20 - 30
2" - 50 mm
JTM - 1140
30 - 40
3" - 80 mm
JTM - 1160
40 - 60
4" - 100 mm
JTM - 1180
60 - 75
5" - 125 mm
JTM - 1220
75 - 150
6" - 150 mm
JTM - 1220
150 - 200
8" - 200 mm
JTM - 1240
200 - 350
10" - 250 mm
JTM - 1250
350 - and above
12" - 300 mm
ON ORDER : Maximum Working Flow RAte/ Nature of fluid, liquid, gas operating condition, construction of material Type of Eng. fitting, special Requirement if any.

All Rights Reserved © Bellstone-Hitech-International